Metal Enclosed Load-Interrupter Switchgear With S&C Components 4.16kV through 34.5kV UL Listed to 15KV |
![]() |
| Jump to
15kV
Switch and Metering Cubicle
| |
|
|
|
Configurations are Limited Only by Your ImaginationEach unit features welded steel construction with wide-view windows that allow checking switchgear without opening mg doors. Corrosionproof, rainproof louvers at the bottom and top, and space heaters inside each unit maintain air cir- culation to keep the interior dry. Three point cam-type, high- strength latches seal the doors shut. The lockable latches and screened louvers discourage tampering. |
| Wide bulkhead doors provide easy access to all bays. Each full-length door has durable heavy-duty hinges with brass pivots. Foot operated holders lock the doors open and give ample room for pulling cables and making terminations. All interrupter switches are maintenance-free and are available in 200, 600 and 1200 amp ratings. S&C Power Fuses provide full-fault-spectrum protection. The switches are manually operated by nonremovable switch handles. Bus connections are silverplated copper for long life. Continuous ground bus in multibay lineups has a short-circuit rating equal to that of the integrated assembly. The MV meter bays are built to utility specifications and multibay lineups are assembled with a minimum of interbay bolting. Call today and discuss your requirements with a Park sales representative. |
|
Ratings of S&C Mini-Ruptor Switches | ||||||||
| kV | Amperes, RMS | Fault Close Duty Cycle* | ||||||
| Cont. | Interrupting | Momentary & Fault Close (Assym kA) | ||||||
| Nom. | Max.Des. | BIL | Load | Cap. | Amperes, RMSMag. | |||
| 5 | 5.5 | 60 | 600 | 600 | 35 | 21 | 40 | 2 |
| 5 | 5.5 | 60 | 1200 | 1200 | 35 | 21 | 61 | 2 |
| 15 | 17 | 95 | 600 | 600 | 35 | 21 | 40 | 2 |
| 15 | 17 | 95 | 1200 | 1200 | 35 | 21 | 61 | 2 |
| 25 | 27 | 125 | 600 | 400 | 100 | 21 | 40 | 2 |
| 34.5* | 38 | 150 | 600 | 600 | 35 | 21 | 28 | 2 |
| * Only available as Alduti SW | ||||||||
Physical Sizes & Park Numbers | ||||
| Park No. | Voltage kV |
Height | Depth | Width |
| PM 315-4.8 | 4.8 | 104" | 44" | 42" |
| PM 315-15 | 15 | 104" | 44" | 42" |
| PM 315-25 | 25 | 120" | 44" | 47" |
| PM 315-35 | 34.5 | 130" | 70" | 60" |
| PM 315-CT | PT/CT Bay | To Match | To Match | 42" |
| PM 315-WM | Meter Bay | To Match | To Match | 42" |
| To order specify current rating & fuse size. | ||||
15kV Primary Switch and Metering Cubicle [PM123] Featuring S&C Components 4.16KV - 34.5kV [UL Listed up to 15KV] |
![]() |
|
|
|
| ![]() |
Configurations are Limited Only by Your Imagination | |
| Each unit features welded steel construction with wide- view windows that allow checking switchgear without opening mg doors. Corrosionproof, rainproof louvers at the bottom and top, and space heaters inside each unit maintain air cir- culation to keep the interior dry. Three point cam-type, high- strength latches seal the doors shut. The lockable latches and screened louvers discourage tampering. Wide bulkhead doors provide easy access to all bays. Each full-length door has durable heavy-duty hinges with brass pivots. Foot operated holders lock the doors open and give ample room for pulling cables and making terminations. |
All interrupter switches are maintenance-free and are available
in 200, 600 and 1200 amp ratings. S&C [TRADEMARK GOES HERE]
Power Fuses provide full-fault-spectrum protection. The switches
are manually operated by nonremovable switch handles. Bus
connections are silverplated copper for long life. Continuous
ground bus in multibay lineups has a short-circuit rating equal
to
that of the integrated assembly. The MV meter bays are built to
utility specifications and multibay lineups are assembled with a
minimum of interbay bolting.
Call today and discuss your requirements with a Park sales
representative.
|
Ratings of S&C Primary Switch | ||||||||
| kV | Amperes, RMS | Fault Close Duty Cycle* | ||||||
| Cont. | Interrupting | Momentary & Fault Close (Assym kA) | ||||||
| Nom. | Max.Des. | BIL | Load | Cap. | ||||
| 15 | 17 | 95 | 600 | 600 | 35 | 21 | 40 | 2 |
Physical Sizes & Park Numbers | ||||
| Park No. | Voltage kV |
Height | Depth | Width |
| PM 123-4.8 | 4.8 | 82" | 60" | 40" | PM 123-15 | 15 | 82" | 60" | 40" |
| To order specify current rating & fuse size. | ||||
NOTE: Front and rear clearance of 4' required, 2' on right for handle operation.
![]() | PARK
DETROIT PARK ELECTRIC PARK FABRICATING POWER DISTRIBUTION SYSTEMS |
19197
Sherwood Avenue Detroit, Michigan 48234 313/366-2200 Fax: 313/366-1540 Email: parkdet@ix.netcom.com |
Comments to jnr at Insight Web Designs